These ramps are at the commencement of the lift and at the closing of the lift, at either end of the base circle area. These ramps are designed to slow the acceleration of the opening of the valve and to slow down the closing of the valve. These ramps prevent damage to the valve train and softens the seating contact during closing to prevent valve and seat damage. See answer to question "24 of general engine questions"